247. Quick Release Main Wiring Harness Kit Installation

SUBJECT: Quick Release Main Wiring Harness Kit Installation REVISION: 02 MODELS: Most Royal Vendors, Dixie-Narco, and Vendo models (115 VAC) PURPOSE: The Quick Release Main Wiring Harness Kits are designed to replace several different Royal Vendors, Dixie-Narco, and Vendo OEM main wiring harnesses. Four kits are available for replacing the original main wiring harnesses. The Universal kit … [Read more...]

234. Universal Caster Kit Installation

SUBJECT: Universal Caster Kit Installation REVISION: 02 MODELS: All venders (not coolers) PURPOSE: This bulletin explains the procedure for installing the Universal Caster Kit on all vender models. Download PDF: Service Bulletin 234 … [Read more...]

288. North American Daylight Saving Time Update

SUBJECT: North American Daylight Saving Time Update REVISION: 00 MODELS: MOST (see bulletin) PURPOSE: Effective the 1st of July, 2007, all Royal Vendors controllers in current production are compliant with the new regulations concerning Daylight Saving Time (DST) in North America. This bulletin describes the correct procedure for updating certain controllers which are already in the market … [Read more...]

283. GFCI Main Wiring Harness Implementation

SUBJECT: GFCI Main Wiring Harness Implementation REVISION: 00 MODELS: All venders built for use in the USA (including Puerto Rico) and Canada PURPOSE: Effective April 2007, all new venders are required to have a GFCI (Ground Fault Circuit Interrupter) built into the main wiring harness coming from the power source (wall outlet). This change has been legally mandated by Underwriters … [Read more...]

37. Column Jam Clearing in HVV and TDV

Subject: Column Jam Clearing in HVV and TDV Revision: 00 Models: All High Visibility Venders (HVV) and all Triple-Depth Venders (TDV) Tools required: None Estimated time: <5 minutes Purpose: Column jam errors registered by the control board on HVV and TDV models are not self-clearing. Because of this, once the problem has been corrected, those columns will not vend again until the … [Read more...]

267. Refrigeration Issues Caused By Control Board Battery Replacement

SUBJECT: Refrigeration Issues Caused By Control Board Battery Replacement REVISION: 00 MODELS: All Venders with Electronic Refrigeration PURPOSE: Replacing a control board battery could affect the calibration of the vender’s temperature sensor, causing evaporator freeze-ups or warm product. This bulletin explains the corrective procedure for this issue. Download PDF: Service Bulletin 267 … [Read more...]

259. Override Switch Kit for the HVV Controller

SUBJECT: Override Switch Kit for the HVV Controller REVISION: 00 MODELS: HVV PURPOSE: This bulletin explains the procedure for installing an override switch kit in the HVV. Download PDF: Service Bulletin 259 … [Read more...]

18. Ground Strap for the Inner Door

Subject: Ground Strap for the Inner Door Revision: 03 Models: All Venders Tools required: Phillips screwdriver, drill, 1/8” drill bit Estimated time: 1 minute Purpose: For instructions on installing a ground strap to the inner door. Download PDF: Helpful Hint 18 … [Read more...]

6. Preventive Maintenance for Ballast Assembly

Subject: Preventive Maintenance for Ballast Assembly Revision: 03 Models: All Venders with Ballast Assembly Tools required: None Estimated time: 10 minutes Purpose: To obtain maximum efficiency of the ballast. Download PDF: Helpful Hint 6 … [Read more...]

5. Leveling leg adjustment to encourage water drainage to the rear of vender

Subject: Leveling leg adjustment to encourage water drainage to the rear of vender Revision: 01 Models: All venders Tools required: Adjustable wrench Estimated time: 3 minutes Purpose: To promote water drainage to the rear of the vender, instead of towards the door seal. Download PDF: Helpful Hint 5 … [Read more...]